新風機組(zu)和(he)空調(diao)機組(zu)區別一:
新(xin)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)組是用來處(chu)(chu)理新(xin)風(feng)(feng)(feng)(feng)(feng)的(de),在一(yi)座大形建筑內,一(yi)般(ban)(ban)新(xin)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)組是和風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)盤管(guan)(guan)配合(he)起來使用,風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)盤管(guan)(guan)+新(xin)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)其(qi)實就(jiu)和空(kong)(kong)調(diao)機(ji)(ji)差不多了。一(yi)般(ban)(ban)情況(kuang)下,空(kong)(kong)調(diao)機(ji)(ji)本(ben)身有(you)新(xin)風(feng)(feng)(feng)(feng)(feng)口,新(xin)風(feng)(feng)(feng)(feng)(feng)用來保證室(shi)內空(kong)(kong)氣的(de)質量,并補充室(shi)內排(pai)風(feng)(feng)(feng)(feng)(feng)。由(you)于風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)盤管(guan)(guan)沒有(you)新(xin)風(feng)(feng)(feng)(feng)(feng)口,所以需要新(xin)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)提(ti)供(gong),新(xin)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)組提(ti)供(gong)的(de)經(jing)過(guo)處(chu)(chu)理的(de)新(xin)風(feng)(feng)(feng)(feng)(feng)和經(jing)過(guo)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)盤管(guan)(guan)處(chu)(chu)理過(guo)的(de)回風(feng)(feng)(feng)(feng)(feng),或者是先混合(he)再由(you)風(feng)(feng)(feng)(feng)(feng)機(ji)(ji)盤管(guan)(guan)處(chu)(chu)理,然(ran)后送入房間內。
新風(feng)機(ji)組和(he)空調機(ji)組區別(bie)二:
新(xin)風(feng)(feng)機組(zu)主要處理室(shi)外空(kong)(kong)氣,而空(kong)(kong)調機組(zu)用(yong)于處理經過新(xin)風(feng)(feng)機處理的(de)空(kong)(kong)氣,但是(shi)新(xin)風(feng)(feng)機可(ke)(ke)以(yi)(yi)有(you)回風(feng)(feng),回風(feng)(feng)也可(ke)(ke)以(yi)(yi)有(you)新(xin)風(feng)(feng),其目的(de)都是(shi)為了更好的(de)調節溫度和濕度等參數(shu)。
新風(feng)機組和(he)空調機組區別三(san):
新風(feng)(feng)機(ji)組一般來說(shuo)不(bu)承擔空調區域的熱濕(shi)負荷,主要功能(neng)就是(shi)送(song)新風(feng)(feng),當然理想(xiang)狀態是(shi)送(song)風(feng)(feng)的溫度(du)和(he)濕(shi)度(du)恒定了(le),所以新風(feng)(feng)機(ji)組一般控制送(song)風(feng)(feng)溫濕(shi)度(du)。
新風(feng)機組和空(kong)調機組區別四:
空(kong)(kong)調(diao)機組負荷空(kong)(kong)調(diao)區域(yu)的(de)(de)熱濕負荷,對空(kong)(kong)調(diao)區域(yu)的(de)(de)空(kong)(kong)氣起到綜合處理的(de)(de)作(zuo)用,同時保證一定的(de)(de)新(xin)風量(liang)。空(kong)(kong)調(diao)機組通(tong)常主(zhu)要是控制空(kong)(kong)調(diao)區域(yu)的(de)(de)溫度濕度和空(kong)(kong)氣質(zhi)量(liang)等,空(kong)(kong)氣處理過(guo)程一般(ban)比(bi)較復雜(za)。
新(xin)風機(ji)(ji)組(zu)和空調機(ji)(ji)組(zu)區(qu)別五(wu):
空(kong)(kong)(kong)調機(ji)組(zu)對于(yu)空(kong)(kong)(kong)氣處理較新(xin)風機(ji)組(zu)在工(gong)藝上要相對復雜,所以空(kong)(kong)(kong)調機(ji)組(zu)多應用(yong)在不能(neng)安裝風機(ji)盤管的(de)大范圍(wei)(wei)公共區域,而新(xin)風機(ji)組(zu)多配合安裝有(you)風機(ji)盤管的(de)小范圍(wei)(wei)空(kong)(kong)(kong)間(jian)使(shi)用(yong)。
無論是(shi)空調機(ji)組還是(shi)新風(feng)機(ji)組使用和(he)(he)安裝(zhuang)都較為普遍(bian),新風(feng)機(ji)組和(he)(he)空調機(ji)組有(you)所區別,但(dan)可以功能(neng)互(hu)補,舒適(shi)100建議大(da)家安裝(zhuang)新風(feng)機(ji)組的同時,然后(hou)每個房間內再單獨安裝(zhuang)風(feng)機(ji)盤(pan)管,這(zhe)樣可以做到取長補短,同時還可以達(da)到更加節能(neng)舒適(shi)的目(mu)的。
四季風新風機組(zu)工作原理(li)
電(dian)(dian)(dian)動(dong)(dong)調(diao)節(jie)閥(fa)(fa)與(yu)風(feng)機(ji)連鎖,以保證切斷(duan)風(feng)機(ji)電(dian)(dian)(dian)源(yuan)時(shi)(shi)風(feng)閥(fa)(fa)亦同時(shi)(shi)關閉(bi)。電(dian)(dian)(dian)動(dong)(dong)調(diao)節(jie)閥(fa)(fa)亦可實現與(yu)風(feng)機(ji)的聯動(dong)(dong),當風(feng)機(ji)切斷(duan)電(dian)(dian)(dian)源(yuan)時(shi)(shi)關閉(bi)電(dian)(dian)(dian)動(dong)(dong)調(diao)節(jie)閥(fa)(fa)。新(xin)風(feng)機(ji)組(zu)溫度控(kong)(kong)制(zhi)系統由比(bi)例積分溫度控(kong)(kong)制(zhi)器(qi)(qi)、安裝在送(song)風(feng)管內的溫度傳感器(qi)(qi)和(he)電(dian)(dian)(dian)動(dong)(dong)調(diao)節(jie)閥(fa)(fa)組(zu)成。控(kong)(kong)制(zhi)器(qi)(qi)的作用是把置于送(song)風(feng)風(feng)道的溫度傳感器(qi)(qi)所檢測到的送(song)風(feng)溫度傳送(song)至溫控(kong)(kong)器(qi)(qi)與(yu)控(kong)(kong)制(zhi)器(qi)(qi)設(she)定的溫度進行(xing)比(bi)較(jiao),并(bing)根據(ju)PI運算的結果(guo),溫控(kong)(kong)器(qi)(qi)給電(dian)(dian)(dian)動(dong)(dong)調(diao)節(jie)閥(fa)(fa)一個開/關閥(fa)(fa)的信號,從而使送(song)風(feng)溫度保持在所需要(yao)的范圍。
當過濾網堵塞時(shi)或當其超過規(gui)定值時(shi),壓差開關(guan)給出開關(guan)信號。
在(zai)(zai)需要(yao)制(zhi)冷時,溫(wen)控(kong)器置于(yu)制(zhi)冷模(mo)式,當傳(chuan)感器測(ce)量的(de)(de)溫(wen)度(du)達(da)到(dao)或低(di)于(yu)設定(ding)(ding)溫(wen)度(du)時,溫(wen)控(kong)器給電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)一(yi)個(ge)關(guan)(guan)閥(fa)(fa)(fa)(fa)信(xin)號(hao),電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)的(de)(de)關(guan)(guan)閥(fa)(fa)(fa)(fa)接(jie)(jie)(jie)點(dian)接(jie)(jie)(jie)通閥(fa)(fa)(fa)(fa)門關(guan)(guan)閉(bi)。如果測(ce)量溫(wen)度(du)沒達(da)到(dao)設定(ding)(ding)溫(wen)度(du),溫(wen)控(kong)器給電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)一(yi)個(ge)開閥(fa)(fa)(fa)(fa)信(xin)號(hao),電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)開閥(fa)(fa)(fa)(fa)接(jie)(jie)(jie)點(dian)接(jie)(jie)(jie)通閥(fa)(fa)(fa)(fa)門打開。在(zai)(zai)需要(yao)制(zhi)熱(re)時,溫(wen)控(kong)器置于(yu)制(zhi)熱(re)模(mo)式,當傳(chuan)感器測(ce)量的(de)(de)溫(wen)度(du)達(da)到(dao)或高于(yu)設定(ding)(ding)溫(wen)度(du)時,溫(wen)控(kong)器給電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)一(yi)個(ge)關(guan)(guan)閥(fa)(fa)(fa)(fa)信(xin)號(hao),電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)的(de)(de)關(guan)(guan)閥(fa)(fa)(fa)(fa)接(jie)(jie)(jie)點(dian)接(jie)(jie)(jie)通閥(fa)(fa)(fa)(fa)門關(guan)(guan)閉(bi)。如果測(ce)量溫(wen)度(du)沒達(da)到(dao)設定(ding)(ding)溫(wen)度(du),溫(wen)控(kong)器給電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)一(yi)個(ge)開閥(fa)(fa)(fa)(fa)信(xin)號(hao),電(dian)(dian)(dian)動閥(fa)(fa)(fa)(fa)開閥(fa)(fa)(fa)(fa)接(jie)(jie)(jie)點(dian)接(jie)(jie)(jie)通閥(fa)(fa)(fa)(fa)門打開。
當(dang)盤管(guan)溫(wen)度過低時,低溫(wen)防凍(dong)開(kai)關給出開(kai)關信號,風機停止運行,防止盤管(guan)凍(dong)裂。
新風機組原(yuan)(yuan)理(li)和(he)中(zhong)央空調相比(bi)不算復雜,新風機組分(fen)為(wei)單向(xiang)(xiang)流(liu)、雙向(xiang)(xiang)流(liu)新風機和(he)全熱(re)交換新風機,前兩種新風機組原(yuan)(yuan)理(li)更為(wei)簡單,而全熱(re)交換新風機有節能(neng)溫度控制系(xi)統,工作原(yuan)(yuan)理(li)復雜一點,使(shi)用效(xiao)果也(ye)是最好的(de),當然,價格(ge)也(ye)是最貴的(de)。
新風機組功能段
新風機組有多(duo)個功能段,大致包(bao)括以下幾個,
過濾段:
根(gen)據需(xu)要選配粗(cu)效(xiao)過濾器(qi)、中效(xiao)過濾器(qi)、高效(xiao)過濾器(qi)等,主要用于有效(xiao)捕(bu)集顆粒(li)(li)直徑不等的塵(chen)粒(li)(li)。
表冷段:
用表冷(leng)器對(dui)新風進行冷(leng)卻、減濕,控制(zhi)送風溫、濕度。
加濕段:
使用電極加濕、蒸汽加濕等,可(ke)以保證(zheng)較嚴的相(xiang)對濕度(du)要求
風機段:
可根據需要(yao)選(xuan)用(yong)離心風機、軸流風機,一般選(xuan)用(yong)的是(shi)離心風機。
殺菌段:
如紫外燈殺菌。
以(yi)(yi)上(shang)為常規各個(ge)(ge)空(kong)氣處理段(duan),可以(yi)(yi)實(shi)現(xian)空(kong)調房間(jian)人體對溫度(du)、濕度(du)、空(kong)氣潔凈(jing)度(du)的(de)要求。另外,考慮到(dao)節(jie)能需要,新(xin)(xin)風機組除了(le)以(yi)(yi)上(shang)幾個(ge)(ge)功能段(duan)外,還可能配(pei)備(bei)熱回收段(duan),熱回收段(duan)是(shi)采用熱回收裝(zhuang)置(zhi)回收排風中的(de)冷熱量來對新(xin)(xin)風進行預冷或預熱,從(cong)而實(shi)現(xian)能量的(de)回收利用。
新風機設備選型步驟如下(xia):
1、據安裝設置選擇新風(feng)機的形式;
2、設備風(feng)量(liang)、風(feng)壓選(xuan)用(yong)時以不小于設計值為(wei)原則;
3、確(que)定制冷量(liang)及制熱(re)量(liang)的設計工(gong)況;
4、原則上一臺新風(feng)機(ji)組只負(fu)責一層樓面所需(xu)的新風(feng)量。